Safety Instructions for Emergency Rescue
Chapter 7 · Manual page 300
- Please always observe the high-voltage safety precautions during rescue. The safety of rescue personnel and any by standers is priority.
- Vehicle components with high-voltage warning labels and orange harnesses are high-voltage components.
- Please always follow the safety requirements on the warning labels fitted to the high-voltage system.
- Work on high-voltage components must be performed by qualified personnel, and the operators must always wear suitably insulated personal protective equipment and use insulated tools.
- When working on high-voltage components, the high voltage must be disconnected by strictly following the operation instructions of “High Voltage Disconnection” in this Handbook to ensure safety before proceeding.
- Never damage the high-voltage battery pack when lifting the vehicle from below. Please take extra care to ensure that the floor is not damaged when using rescue tools.
- Regardless of the operations, care should always be taken with all high-voltage components, and cutting, squeezing or touching high-voltage components, failure to observe these instructions may cause severe injury or death.
Protective equipment Work on high-voltage components must be performed by qualified personnel, and the operators must be provided with the correct insulated personal protective equipment and use insulated tools.
Insulating Protective Equipment and Insulating Tools Illustration
Insulating gloves, withstand voltage 1kV
Insulating shoes, withstand voltage 18kV
Insulating tools, withstand voltage 1kV
Insulating pad, withstand voltage 10kV